Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the updraftplus domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/algas/public_html/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the rocket domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/algas/public_html/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the breadcrumb-navxt domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/algas/public_html/wp-includes/functions.php on line 6114
Flow Meter - Vemmtec IGTM Turbine Meter - Algas

Flow Meter – Vemmtec IGTM Turbine Meter

Flow Meter - Vemmtec IGTM Turbine Meter

The vemm tec IGTM-CT Gas Turbine Meter is a highly accura-te flow meter, approved for custody transfer measurement, equipped with electronic pulse outputs and a mechanical counter. This document explains the performance, ranges, dimensions, calibration and outputs of the instrument. It details the installation, safety requirements and material speci-fications.

Technical Specification

01.

Main Features:

Material of Construction :

  • Housing : Ductile Iron (EN-GJS-400-18-LT)
  • Carbon Steel (Cast or Welded)
  • Carbon Steel (Cast or Welded) Stainless Steel (on request)
  • Straightening Vane : Aluminium
  • Turbine Wheel : Aluminium
  • Metering Insert : Aluminium
  • Bearing Block : Aluminium
  • Bearings : Stainless Steel
  • Shafts : Stainless Steel
  • Gears : Stainless Steel or Synthetic Material
  • Magnetic Coupling : Stainless Steel
  • Index Head : Aluminium

Material and Safety Tests

  • Hydro test at 1.5 x maximum operating pressure
  • Air seal test at 1.1 x maximum operating pressure
  • Material certificate per EN 10204 3.1
  • CE-PED compliance: Directive 97/23/EC
  • Electronic sensors are approved according to ATEX”

Accuracy
Standard accuracy limits for the IGTM-CT are in accordance with the MID directive (2004/22/EC) and many other regulations:
± 1% for 0.2 Qt to Qmax (Range 1:20: Qt = 0.2 Qmax)
± 2% for Qmin to 0.2 Qt (Range ≥1:30: Qt = 0.2 Qmax)

As an option the accuracy limits can be improved to:
± 0.5% for 0.2 Qt to Qmax
± 1% for Qmin to 0.2 Qt”